Eurathane® 3000 should be applied by brush, roller or trowel to obtain a continuous, unbroken film. It should be applied at a rate of 0.75 litre/m2/coat. Two coats are recommended, allowing the first to fully dry prior to application of the second. A dry film thickness of 1.0 mm to 1.2 mm is recommended.
Apply Eurathane® 3000 Top Coat at a rate of 0.2 kg to 0.3 kg per sqm where Eurathane® 3000 is to be exposed to weather.
Extremely porous substrates should be primed with a high penetration solvent-based polyurethane primer prior to coating. Application must be made uniformly to avoid pin holes.
As with all waterproofing treatments, it is essential that Eurathane® 3000 is protected from mechanical damage during subsequent construction work or backfilling.
Eurathane® 3000 is resistant to frost, but adhesion may be impaired when applied to substrates that are frozen or frosted. Treatment should be avoided if temperatures are likely to fall below 5ºC during application.
Surfaces upon which Eurathane® 3000 is to be applied should be dry, smooth, sound and free from honeycombs, protrusions, voids, laitance, dust, loose material, paint, oil, curing agent or any other contaminants. Blockwork should be smoothly rendered and brickwork flush pointed.